Seitenansicht 26
22 Configuration MoTeC
Connections
Configuring Inputs
On the Connections menu, click Devices
Select the device (e.g. C185) and then click the Input pins tab
This will list all inputs available for this product
Note: Some inputs require the 52 I/O Upgrade to make them available.
See C185 Upgrades
Select the input and click Channel (or double click the input)
Assign a measurement channel to the input and click OK
The channel needs to be calibrated using one of two options
Select Load Cal if a pre-defined calibration is available
OR
Double-click the input to enter a calibration
Other tasks:
Change Cal – to change the calibration
Spd Levels – only for speed inputs
Settings – to set default
Configuring Outputs
On the Connections menu, click Devices
Select device (e.g. C185) and then click the Output Pins tab to list all
outputs available for this product
Note: Some outputs require 52 I/O Upgrade to make them available. See
C185 Upgrades.
Select the output and click Change (or doubleclick the output)
Select a mode to make appropriate settings available
Follow the directions on the screen and when all settings are done click
OK
Configuring Communications
On the Connections menu, click Communications
Select an available communications section (CAN or RS232)
Click Select and choose one of the available communications templates