User Manual
USING M1 TUNE
Printed documents are not controlled Page 51
11.7 Q CALIBRATE FUNCTIONS
The Q key performs special functions on parameters and tables that were not available in older
ECUs. The function is different depending on the selected item.
Note: The Q function can now perform a calibrate against any parameter or table
displaying the Q icon.
For example
When the item is selected, and the Q key pressed, M1 Tune performs a special function that will
generally calibrate that value.
An example of this is setting throttle position high and low values. The process for this would be
as follows:
1. Select the Throttle Pedal Main Closed parameter.
2. Close the throttle and press the Q key.
The current pin voltage is determined and Throttle Pedal Main Closed parameter is set to
that value.