Motec ACL VIM Bedienungsanleitung Seite 79

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 99
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 78
MoTeC Appendices 75
ACL Errors
These errors are generated by the ACL communications system.
2 FRAMING Incorrect number of samples received.
256 BAD CONFIG Configuration mismatch between ACL
and device. Resend the configuration.
512 NO DATA VIMCOM packets have not been found.
Either there is a wiring fault or ACL
Connections is setup incorrectly.
2048 WRONG DATA VIMCOM packet has bad length.
4096 BUS WARNING More than 96 errors have occurred on
the CAN bus. Check wiring and
termination resistors. The CAN bus may
still be operational.
8192 BUS OFF More than 255 errors have occurred on
the CAN bus. CAN communications is
suspended when this error occurs.
Check wiring, termination resistors and
the CAN baud rate. Also check that CAN
HI and CAN LO are correct (not
swapped).
VIMCOM Device Errors.
These error codes are sent once by the VIMCOM device on resuming
data transmission and therefore indicate why data was previously not
being transmitted.
4097 STARTUP Device has restarted (normally due to
power up) Data is not sent until sync is
achieved.
4098 HALT Data not sent due to deliberate halt. For
example configuration or firmware being
sent.
4099 OVERRUN Data not sent due to transmit buffer
overrun (possibly due to CAN bus too
busy)
4100 SYNC TIMEOUT Data not sent due to ACL sync message
timeout (sync not received from ACL)
4101 CAN ERROR Data not sent due to error on CAN bus
Seitenansicht 78
1 2 ... 74 75 76 77 78 79 80 81 82 83 84 ... 98 99

Kommentare zu diesen Handbüchern

Keine Kommentare